In compliance with the Grand Jury recommendations CUSD released AHERA reports for CUSD school sites
San Clemente High School - a case study

The ABCs Of Asbestos in Schools
Source: https://www.epa.gov/sites/production/files/documents/abcsfinal.pdf
Districts are required to develop, maintain, and update an asbestos management plan and keep a copy at the District Office for public inspection. Also- each individual school should have a copy of the plan for their individual school.
Find out what's happening in Mission Viejofor free with the latest updates from Patch.
For a complete list of School Asbestos Management Plan Requirements, see the Asbestos-Containing Materials in Schools Rule:
https://www.epa.gov/asbestos/code-federal-regulations-chapter-40-part-763-asbestos
For an example of what a plan should be see the Model AHERA Asbestos Management Plan for Local Education Agencies:
https://www.epa.gov/asbestos/model-ahera-asbestos-management-plan-local-education-agencies
San Clemente High School - a case study
AHEAR Contact for CUSD
Original Inspection:
The 1989 AHERA report showed Asbestos at San Clemente High School at the following locations with records reflecting what actions CUSD has taken to ABATE Asbestos issues at San Clemente High School:
Find out what's happening in Mission Viejofor free with the latest updates from Patch.
Item #1 on page 2 of Report: Building 500
Item #2 on page 3 of Report: Building 700
- Ceiling Panel - 11,300 square feet - (Re-sampled 5-9-91 No Asbestos Detected)
Item #3 on page 3 Building 900
- Boiler Room Flex Joint (ABATED 8/91)
Item #4 on page 4 Triton Center - Kitchen
- Wrestling Room Vinyl Floor Tile (REMOVED Summer 1990 - no supporting documentation provided)
- Teachers Lounge 500 Flat Acoustic Spray on (ABATED 1-91)
- Cafeteria (1000 or 2000) square feet (1000 square feet ABATED 5/97)
- Flat Acoustic Spray on (ABATED 5/97 )
- Cafeteria Vinyl Floor Tile (1000 or 2000) square feet (ABATED 7/97)
Item #5 Library on page 4
- Exterior Wall A/C panel no documentation that this was completed
Item #6 Shops 2 & 3 on page 4
- 4,400 square feet of flat acoustic spray Edge of Library, Back of Stage (Re-sampled 5/25/1990 - No Asbestos detected)
- Storage Room Elbow Hot Water Supply (ABATED 8-91)
Item #7 Building S2 - Shops 4 & 5 on page 5
- Boiler Room Flex Joint (ABATED 8-91)
Item #8 Building S3 - Shops 9, 10, 11 on page 5
- Vinyl Floor Tile 6000 square feet (S2 4 & 5 Office ABATED 8-92 through 8-94) (PARTIAL ABATEMENT DOCUMENTED - Room S4 only)No documentation that S2 5 & Office were completed
Item #9 Theater Entrance on page 6
- Room 59 A/C/Panel 500 Square Feet. No documentation that S2 5 & Office were completed
- Flat Acoustic Spray On 6000 square feet(1000 square feet ABATED 8/91)
Following the initial inspection, districts are required to re-inspect asbestos-containing material in each school every three years and to report findings in an "asbestos management plan".
The following is San Clemente High School's 3-Year Inspection Dates. Asbestos Management Plan from 1989 to the present.
| LATEST CERTIFICATION OF 3 YEAR RE-INSPECTION DATED APRIL 6, 2015 | |
![]() ![]() ![]() ![]() ![]() |
For each Item, the district is required to keep specific records as to what actions the district has taken to ABATE asbestos contamination.
| LATEST 6- MONTH PERIODIC INSPECTION DATED November 18, 2016 |
![]() ![]() ![]() ![]() ![]() ![]() |
Both the current 3-Year inspection dated 4/6/15 and the current 6-month Periodic inspection show that there is still (after 28 years) ASBESTOS in San Clemente High that CUSD needs to contain- maintain - ABATE. Records are missing and/or are incomplete.
The District needs to take the most recent inspection reports, determine the cost to ABATE each item and make a plan to complete repairs and should not be allowed to wait another 20 years to complete their work.
The Grand Jury provided districts with 20 recommendations in an effort to get school districts in compliance with the AHERA laws. CUSD's current Facilities Maintenance Plan for San Clemente High is not budgeting funds for these repairs.
The following are the listed expenditures for San Clemente High School from the present to 2021:
- Fire Alarm $750,000
- Carpet $18,000
- Football Field $785,000
Total: $1,553,000.00 over 5 years
Source:
http://capousd-ca.schoolloop.com/file/1456826680226/1446974333195/4035841103000775946.pdf